Continuous-time survival refutation verdict rules#

This study calibrates two rules that cleverly.refute prints on a risk difference of a ContinuousSurvivalTMLE fit. The “Continuous-time survival refutation” paragraphs under Refutation operations in the validation reference define the draws and their references.

rule

reading

rejects when

placebo t

20 refits on the treatment permuted among the units, against the exact null 0 of a risk difference, t with 19 degrees of freedom

the two-sided p-value is below 0.05

subset rho

20 refits on 700 of the 1,000 units, each keeping its outer fold, against the sampling reference of the fit’s standard error

the two-sided \(\chi^2_{19}\) p-value is below 0.05

The study asks two questions for each risk difference. Is the rule grossly miscalibrated under its null? Does the rule detect a declared defect? A rule that passes both checks prints a verdict on a fit inside the calibrated scope. On any other fit, the rule prints its numbers and no verdict.

No canonical implementation is compared. No maintained implementation computes these rules on a continuous-time survival fit. The zero-row equivalence artifact records the absence of a comparator.

What was tested#

setting

declaration

sample

\(n = 1000\) units, one fit per trial: the default ContinuousSurvivalTMLE with ten outer and five inner folds, the default Cox hazard libraries and treatment learner, and the switched variance. 20 refits per reading

size law

the registered base law of continuous-time-survival: two causes, independent censoring, about half treated, and an arm-specific term in the cause-1 hazard

estimands

the risk difference of each cause at the median (1.12) and upper quartile (2.32) of the observed event times. The target times hold 43% to 56% and 70% to 79% of the observed events over the size trials

size cells

600 trials. Each trial’s eight readings come from the same 41 fits. A cell passes at no more than 68 rejections

power cells

50 trials on a power law that raises the arm-specific term to 2.0 and the cause-2 arm coefficient to -1.0, under a placebo that keeps 35% of the recorded treatments; and size trials 0 to 49 read with the reported SE halved and doubled. A cell passes at no fewer than 38 detections

reporting cells

100 trials each, placebo only, with censoring that depends on the arm and the covariates, and with about 25% treated. No verdict

primary phase

200 replications of the four differences against their exact truths, as a sanity check of the fit that the rules read

Monte Carlo inference

exact 99% intervals around every rate, and 99% intervals around every primary endpoint

The X101 plan (rev 2, section 5) fixed the laws, the cells, the seeds and the red-cell route before the run. The plan declared 200 size trials and the X82 rule of at most 17 rejections, and required a predictive family pass of 0.90 before the declaration. The 200-trial pilot read 0.39 at that size. The owner amended the size cells on 2026-11-19 to 600 trials at no more than 68 rejections, the largest count whose 99% Clopper-Pearson upper endpoint (0.1506) stays under the ceiling of the X82 rule’s 17 of 200 (0.1517, midway between the endpoints at 17 and 18 of 200). The module docstring of tests/studies/refuter_calibration_continuous_survival.py states each law and defect, and tests/unit/test_refuter_calibration_continuous_survival_design.py reads the pilot.

The amended size cell is looser than the X82 rule. A rule with true size 0.05 passes with probability 1.000, 0.08 with 0.998, 0.10 with 0.875, and 0.15 with 0.006. Under 17 of 200 a rule at 0.10 passes with probability 0.285. A power cell with 50 trials passes with probability 1.000 at true power 0.95 and 0.814 at true power 0.80.

Accuracy against known truth#

The primary phase checks the fit that the rules read. It does not calibrate the rules.

law

estimand

what was tested

implementation

bias (99% interval)

coverage

SE ratio

result

the registered two-cause continuous-time survival law at n = 1,000; the default ContinuousSurvivalTMLE at ten folds

ate_regimen[treated vs control, cause1 @ t=1.12]

difference in the risk of cause 1 by t = 1.12 between treatment and no treatment

cleverly fit that the continuous-time survival refutation rules read

-0.0043 to 0.0075

0.9550

1.0003

pass

the registered two-cause continuous-time survival law at n = 1,000; the default ContinuousSurvivalTMLE at ten folds

ate_regimen[treated vs control, cause1 @ t=2.32]

difference in the risk of cause 1 by t = 2.32 between treatment and no treatment

cleverly fit that the continuous-time survival refutation rules read

-0.0068 to 0.0051

0.9500

1.0506

fail

the registered two-cause continuous-time survival law at n = 1,000; the default ContinuousSurvivalTMLE at ten folds

ate_regimen[treated vs control, cause2 @ t=1.12]

difference in the risk of cause 2 by t = 1.12 between treatment and no treatment

cleverly fit that the continuous-time survival refutation rules read

-0.0018 to 0.0083

0.9400

1.0131

fail

the registered two-cause continuous-time survival law at n = 1,000; the default ContinuousSurvivalTMLE at ten folds

ate_regimen[treated vs control, cause2 @ t=2.32]

difference in the risk of cause 2 by t = 2.32 between treatment and no treatment

cleverly fit that the continuous-time survival refutation rules read

0.0014 to 0.0129

0.9600

1.0350

fail

Theory properties#

A refuter_size cell counts the rejections of a rule under its null. A refuter_power cell counts the detections of a defect. The cell name gives the estimand, then the reading.

property

cell

role

what was tested

what must hold

measured

result

refuter_power

c1_t1.12__placebo_stale_rows

control

the cause-1 risk difference at t = 1.12: the placebo t rule, with 35% of rows keeping their treatment

at least 38 detections in 50 trials

detections 50 of 50

pass

refuter_power

c1_t1.12__subset_double_se

control

the cause-1 risk difference at t = 1.12: the subset rho rule, at the reported SE doubled

at least 38 detections in 50 trials

detections 48 of 50

pass

refuter_power

c1_t1.12__subset_half_se

control

the cause-1 risk difference at t = 1.12: the subset rho rule, at the reported SE halved

at least 38 detections in 50 trials

detections 49 of 50

pass

refuter_power

c1_t2.32__placebo_stale_rows

control

the cause-1 risk difference at t = 2.32: the placebo t rule, with 35% of rows keeping their treatment

at least 38 detections in 50 trials

detections 50 of 50

pass

refuter_power

c1_t2.32__subset_double_se

control

the cause-1 risk difference at t = 2.32: the subset rho rule, at the reported SE doubled

at least 38 detections in 50 trials

detections 48 of 50

pass

refuter_power

c1_t2.32__subset_half_se

control

the cause-1 risk difference at t = 2.32: the subset rho rule, at the reported SE halved

at least 38 detections in 50 trials

detections 49 of 50

pass

refuter_power

c2_t1.12__placebo_stale_rows

control

the cause-2 risk difference at t = 1.12: the placebo t rule, with 35% of rows keeping their treatment

at least 38 detections in 50 trials

detections 50 of 50

pass

refuter_power

c2_t1.12__subset_double_se

control

the cause-2 risk difference at t = 1.12: the subset rho rule, at the reported SE doubled

at least 38 detections in 50 trials

detections 46 of 50

pass

refuter_power

c2_t1.12__subset_half_se

control

the cause-2 risk difference at t = 1.12: the subset rho rule, at the reported SE halved

at least 38 detections in 50 trials

detections 50 of 50

pass

refuter_power

c2_t2.32__placebo_stale_rows

control

the cause-2 risk difference at t = 2.32: the placebo t rule, with 35% of rows keeping their treatment

at least 38 detections in 50 trials

detections 50 of 50

pass

refuter_power

c2_t2.32__subset_double_se

control

the cause-2 risk difference at t = 2.32: the subset rho rule, at the reported SE doubled

at least 38 detections in 50 trials

detections 48 of 50

pass

refuter_power

c2_t2.32__subset_half_se

control

the cause-2 risk difference at t = 2.32: the subset rho rule, at the reported SE halved

at least 38 detections in 50 trials

detections 50 of 50

pass

refuter_size

c1_t1.12__placebo

positive

the cause-1 risk difference at t = 1.12: the placebo t rule against the exact null 0

no more than 68 rejections in 600 trials

rejections 28 of 599

pass

refuter_size

c1_t1.12__subset

positive

the cause-1 risk difference at t = 1.12: the subset rho rule against the fit’s standard error

no more than 68 rejections in 600 trials

rejections 57 of 599

pass

refuter_size

c1_t2.32__placebo

positive

the cause-1 risk difference at t = 2.32: the placebo t rule against the exact null 0

no more than 68 rejections in 600 trials

rejections 27 of 599

pass

refuter_size

c1_t2.32__subset

positive

the cause-1 risk difference at t = 2.32: the subset rho rule against the fit’s standard error

no more than 68 rejections in 600 trials

rejections 48 of 599

pass

refuter_size

c2_t1.12__placebo

positive

the cause-2 risk difference at t = 1.12: the placebo t rule against the exact null 0

no more than 68 rejections in 600 trials

rejections 33 of 599

pass

refuter_size

c2_t1.12__subset

positive

the cause-2 risk difference at t = 1.12: the subset rho rule against the fit’s standard error

no more than 68 rejections in 600 trials

rejections 55 of 599

pass

refuter_size

c2_t2.32__placebo

positive

the cause-2 risk difference at t = 2.32: the placebo t rule against the exact null 0

no more than 68 rejections in 600 trials

rejections 33 of 599

pass

refuter_size

c2_t2.32__subset

positive

the cause-2 risk difference at t = 2.32: the subset rho rule against the fit’s standard error

no more than 68 rejections in 600 trials

rejections 52 of 599

pass

Result#

All 20 property cells pass. One of the 600 size trials was lost to a recorded fitting failure (a subset refit whose initial hazard fit put a combined jump of one or more at one time), under the failure bound of 0.01, so each size cell reads 599 trials. The engine now bounds such a jump instead of refusing it; refitted under the bound, that trial still fails at the same subset refit, on survival underflow after the bound acted, so the count stands.

The placebo cells reject in 28, 27, 33 and 33 trials, rates of 0.045 to 0.055. The subset cells reject in 57, 48, 55 and 52 trials (cause 1 at 1.12 and 2.32, then cause 2), rates of 0.080 to 0.095. Every subset cell’s 99% interval lies above 0.05, so the subset rule rejects 1.6 to 1.9 times as often as the 0.05 level it targets. It passes because the amended limit tolerates rates up to about 0.11.

The power cells detect their defects in 46 to 50 of 50 trials. The reporting cells reject in 2% to 9% of their trials.

The registry VERDICT_EVIDENCE holds one placebo row and one subset row. Each covers the recorded configuration of the size cells: ContinuousSurvivalTMLE with two causes, the stem ate_regimen, the default learners, the switched variance, ten folds, 20 refits, \(n \ge 1000\), at least 17 events in every arm and cause by the target time, and an event share of 0.4336 to 0.7946. A fit with variance="influence_curve" prints no verdict. The subset row’s sentence states its measured false-alarm rate. tests/unit/test_refuter_calibration_continuous_survival_registry.py checks each scope against the committed run.

Three primary truth rows are red. The cause1 @ t=2.32 row cannot resolve its coverage floor or SE-ratio screen at 200 replications. The cause2 @ t=1.12 row cannot resolve its coverage floor or bias margin. The cause2 @ t=2.32 row reads a bias interval of 0.0014 to 0.0129, which excludes 0 and crosses the margin of 0.0078. Every SE-ratio interval contains 1, and no rule row reads these rows. The red-cell ledger names the owner.

Measured values#

Names beginning margin: are thresholds declared before the run. Everything else is measured from the committed results and checked at the precision printed.

quantity

value

source

replicates

200

primary replications

n

1000

observations per primary replication

independent_tests_total

4

primary tests against truth

independent_tests_passed

1

of those, passing

paired_tests_total

0

external comparisons declared

paired_tests_passed

0

external comparisons passing

property_cells_total

20

repeated-sampling property cells

property_cells_passed

20

cells whose own and family verdicts pass

max_standardized_bias

0.2293

largest absolute primary bias in empirical standard deviations

min_coverage

0.9400

lowest measured primary-study coverage

min_se_ratio_ci_lower

0.8918

lowest bootstrap primary SE-ratio endpoint

max_se_ratio_ci_upper

1.2106

highest bootstrap primary SE-ratio endpoint

margin:confidence_level

0.9900

confidence level of every Monte Carlo interval

margin:alpha

0.0500

nominal size of the reported intervals, and the level of the rule

margin:nominal_coverage

0.9500

nominal coverage those intervals claim

margin:bootstrap_replicates

10000

resamples behind every bootstrap interval

margin:type_i_ceiling

0.1000

the rate a type-I cell must bound. No cell of this study reads it; a size cell reads its count

margin:minimum_power

0.8000

rejection lower bound a power family must clear. No cell of this study reads it; a power cell reads its count

margin:standardized_bias

0.2500

bias equivalence margin, in empirical standard deviations

margin:coverage_floor

0.9000

validity floor the coverage lower endpoint must clear

margin:over_coverage_ceiling

0.9900

above this, coverage is conservative rather than invalid

margin:se_ratio_sanity_lower

0.8000

SE-ratio screen, lower limit

margin:se_ratio_sanity_upper

1.2000

SE-ratio screen, upper limit

margin:calibration_se_ratio_lower

0.9300

calibration-cell SE-ratio band, lower limit. No cell of this study reads it

margin:calibration_se_ratio_upper

1.0700

calibration-cell SE-ratio band, upper limit. No cell of this study reads it

margin:calibration_coverage_lower

0.9200

calibration-cell coverage band, lower limit. No cell of this study reads it

margin:calibration_coverage_upper

0.9800

calibration-cell coverage band, upper limit. No cell of this study reads it

margin:paired_difference

0.1500

paired similarity margin, in pooled empirical standard deviations

margin:rmse_noninferiority

1.1000

largest external-comparison RMSE ratio bound

margin:coverage_noninferiority

-0.0250

smallest external-comparison coverage difference bound

margin:calibration_noninferiority

0.0500

largest external-comparison calibration excess bound

margin:root_n_slope

-0.5000

contraction rate root-n asymptotics predict

margin:root_n_slope_lower

-0.6250

accepted root-n slope band, lower limit

margin:root_n_slope_upper

-0.3750

accepted root-n slope band, upper limit

margin:excluded_slope

-0.2500

slower rate a root-n interval must exclude

margin:subject_failure_bound

0.0100

declared share of replications a cell may lose to a recordable fitting failure

margin:subject_failures_allowed

2

the same bound, in primary replications

Limitations#

limitation

what it means for use

The row publishes under the reporting policy, not gated

The fast tier recomputes each verdict and does not fail on a red one

There is no cross-implementation evidence

No maintained implementation computes these rules on this fit

A looser size tolerance than the X82 rule

A rule with true size 0.10 passes a size cell with probability 0.875. A pass does not certify the size to two decimals, and the subset rule measured 0.080 to 0.095

The subset rule over-rejects

About one fit in eleven fails the subset check with nothing wrong. Read a subset failure with that rate in mind

One law and one size

Each row covers \(n \ge 1000\) at 0.004 covariates per row, two causes and the measured event shares. A smaller fit, a single-cause fit or a target time outside the shares prints no verdict

The default fit only

The rows name the default Cox libraries, each as a whole library, the default treatment learner, ten folds and the switched variance. Any other library, including a subset of a default one, and any other learner, fold count or variance prints no verdict

Risk differences only

A ratio or an arm’s risk prints no verdict

The primary phase is under-resolved

With 200 replications the 99% coverage limit of cause 1 at 2.32 and cause 2 at 1.12 stays under its floor (0.8960 and 0.8829), and cause 2 at 2.32 reads a small bias. These three truth rows are red with an owner, and no rule row reads them

Placebo power was measured on one law

The stale-row placebo cells ran the power law, whose event shares run from 0.54 to 0.85. The rows cover shares down to 0.4336, where the placebo’s power was not measured

Reproduction#

The fixture README gives the regeneration command. The manifest records the seeds, the margins, the laws, the source hashes and the result hashes. The cell configurations and the property results carry every published row.