A declared treatment mechanism beside sample-reading weights#
This study validates mechanism_law="sample": point TMLE and LTMLE on weighted data that
declares the treatment mechanism of the rows as drawn with treatment_probabilities=. The fit
estimates the mechanism of the weight-tilted law as
\(\hat g_w(a\mid W) \propto g_0(a\mid W)\,\hat r(a\mid W)\), where \(\hat r\) is the treatment
learner’s classification of \(A\) on \(W\) with weights \(w/g_0(A\mid W)\). It is an
estimated-mechanism fit, so its interval needs the outcome regression and the tilt classifier
both consistent at a product rate. The section on the
known treatment mechanism states the
construction and its remainder, and the section on
known node mechanisms states it node by node.
The declared run passed every gated verdict, with no failed fit: 3 of 3 primary rows and 26 of
26 property cells. No external package implements the tilted mechanism from a declaration, so
no canonical implementation is compared. The fast tier’s exact-law tests
(tests/unit/test_known_mechanism_weights.py and
tests/unit/test_known_mechanism_weights_longitudinal.py) pin the construction. Its support rows
T56 and G64 require the tilted_mechanism qualifier, so they cover the "sample" route only.
An ordinary weighted fit with an estimated mechanism keys apart, and this study does not license it.
The laws#
SW is a point law whose weight reads \((A, W)\) only, so the tilted ATE keeps its causal reading. \(W_1 \sim N(0, 1)\) and \(W_2 \sim \operatorname{Bernoulli}(0.5)\). The declared randomization is \(g_0(1\mid W) = 0.3 + 0.4 W_2\). The outcome is \(Y \sim \operatorname{Bernoulli}(\operatorname{expit}(-1 + A + W_1 + 1.5 A W_1 - W_1^2/2 + 0.5 W_2))\) and the weight is \(w = \exp(0.4 A + 0.5 A W_1 + 0.15 W_1)\). Then \(E[w \mid A, W] = w\) and the tilt is \(r(1\mid W) = \operatorname{expit}(0.4 + 0.5 W_1)\), so a main-terms logistic classifier is correct for it. The truth is \(\Psi(P_w) = 0.330353\) against an unweighted ATE of 0.234120, and the Kish effective sample size is 0.65 n.
LW is a two-node law. \(L_0 \sim N(0, 1)\), \(A_1 \sim \operatorname{Bernoulli}(\operatorname{expit}(0.4 L_0))\) (declared), \(L_1 \sim N(0.5 L_0 + 0.5 A_1, 1)\), \(A_2 \sim \operatorname{Bernoulli}(\operatorname{expit}(-0.2 + 0.6 L_1))\) (declared), and \(Y = 0.5 L_0 + 0.4 A_1 + 0.5 A_1 L_0 + 0.6 L_1 + 0.5 A_2 + 0.3 A_1 A_2 + N(0, 1)\). The weight \(w = \exp(0.4 A_1 + 0.5 A_1 L_0 + 0.15 L_0)\) tilts the first node and not the second. The target is the contrast of always and never treating, 1.769979 under \(P_w\) against 1.5 in the rows as drawn, and the Kish effective sample size is 0.63 n.
tests/studies/known_sample_weights_law.py defines both laws.
tests/unit/test_known_sample_weights_design.py recomputes every truth by quadrature or a
longhand g-formula and checks it against Monte Carlo, and recomputes each control’s exact-law
bias from the population targeting step.
The fits#
fit |
law |
reading |
outcome regression |
tilt classifier |
|---|---|---|---|---|
|
SW |
|
logistic on \((A, W_1, A W_1, W_1^2, W_2)\), correct |
main-terms logistic on \((W_1, W_2)\), correct |
|
SW |
|
main-terms logistic on \((A, W_1, W_2)\), wrong |
correct |
|
SW |
|
correct |
logistic on \(W_2\) alone, wrong |
|
SW |
|
wrong |
wrong |
|
SW |
|
wrong |
none |
|
LW |
|
weighted least squares at each node, correct |
main-terms logistic per node, correct |
|
LW |
|
intercept-only at node one, wrong |
correct |
|
LW |
|
intercept-only at node one, wrong |
none |
Every point fit cross-fits on five folds with g_bounds=(0.01, 0.99), which no tilted mechanism
reaches. Every LTMLE fit cross-fits on five folds with q_bounds=(-25, 25), which no draw
reaches, and g_bounds=(1e-4, 1.0), which no cumulative product reaches.
Accuracy against known truth#
law |
estimand |
what was tested |
implementation |
bias (99% interval) |
coverage |
SE ratio |
result |
|---|---|---|---|---|---|---|---|
a binary outcome, W1 normal and W2 binary, a declared randomization by W2 and a weight that reads the arm and W1; mechanism_law=’sample’ with a correct logistic outcome regression and a correct main-terms tilt classifier, five folds |
|
average treatment effect |
|
-0.0013 to 0.000678 |
0.9545 |
1.0021 |
pass |
a binary outcome, W1 normal and W2 binary, a declared randomization by W2 and a weight that reads the arm and W1; mechanism_law=’sample’ with a correct logistic outcome regression and a correct main-terms tilt classifier, five folds |
|
counterfactual mean under no treatment |
|
-0.000821 to 0.000790 |
0.9575 |
1.0074 |
pass |
a binary outcome, W1 normal and W2 binary, a declared randomization by W2 and a weight that reads the arm and W1; mechanism_law=’sample’ with a correct logistic outcome regression and a correct main-terms tilt classifier, five folds |
|
counterfactual mean under treatment |
|
-0.000923 to 0.000288 |
0.9405 |
0.9770 |
pass |
The primary rows draw 2,000 samples of 4,000 rows from SW and fit sample_correct.
Theory properties#
property |
cell |
role |
what was tested |
what must hold |
measured |
result |
|---|---|---|---|---|---|---|
|
|
control |
law SW at n = 4,000, the ATE, mechanism_law=’sample’ with the main-terms outcome regression on (A, W1, W2) and a tilt classifier on W2 alone |
99% interval of the standardized bias wholly outside the margin |
bias -0.0354 to -0.0340, margin 0.0042 |
pass |
|
|
positive |
law LW at n = 4,000, the always-versus-never contrast, mechanism_law=’sample’: both nuisances are correctly specified |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9426 to 0.9603, SE ratio 0.9575 to 1.0263 |
pass |
|
|
control |
law LW at n = 4,000, the always-versus-never contrast, mechanism_law=’sample’: a declared scale of independent noise is added to each estimate |
the SE-ratio interval must fall below the calibration band |
coverage 0.8248 to 0.8549, SE ratio 0.6957 to 0.7384 |
pass |
|
|
control |
law LW at n = 4,000, the always-versus-never contrast, mechanism_law=’sample’: the reported standard errors are multiplied by a declared factor below one |
the SE-ratio interval must fall below the calibration band |
coverage 0.8170 to 0.8477, SE ratio 0.6707 to 0.7180 |
pass |
|
|
positive |
law SW at n = 1,000, the ATE, mechanism_law=’sample’: both nuisances are correctly specified |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9361 to 0.9548, SE ratio 0.9653 to 1.0236 |
pass |
|
|
control |
law SW at n = 1,000, the ATE, mechanism_law=’sample’: a declared scale of independent noise is added to each estimate |
the SE-ratio interval must fall below the calibration band |
coverage 0.8163 to 0.8469, SE ratio 0.6912 to 0.7303 |
pass |
|
|
control |
law SW at n = 1,000, the ATE, mechanism_law=’sample’: the reported standard errors are multiplied by a declared factor below one |
the SE-ratio interval must fall below the calibration band |
coverage 0.8049 to 0.8363, SE ratio 0.6756 to 0.7167 |
pass |
|
|
positive |
law SW at n = 16,000, the ATE, mechanism_law=’sample’: both nuisances are correctly specified |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9410 to 0.9589, SE ratio 0.9720 to 1.0295 |
pass |
|
|
control |
law SW at n = 16,000, the ATE, mechanism_law=’sample’: a declared scale of independent noise is added to each estimate |
the SE-ratio interval must fall below the calibration band |
coverage 0.8232 to 0.8534, SE ratio 0.6873 to 0.7281 |
pass |
|
|
control |
law SW at n = 16,000, the ATE, mechanism_law=’sample’: the reported standard errors are multiplied by a declared factor below one |
the SE-ratio interval must fall below the calibration band |
coverage 0.8150 to 0.8457, SE ratio 0.6797 to 0.7213 |
pass |
|
|
positive |
law SW at n = 4,000, the ATE, mechanism_law=’sample’: both nuisances are correctly specified |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9418 to 0.9596, SE ratio 0.9734 to 1.0307 |
pass |
|
|
control |
law SW at n = 4,000, the ATE, mechanism_law=’sample’: a declared scale of independent noise is added to each estimate |
the SE-ratio interval must fall below the calibration band |
coverage 0.8160 to 0.8467, SE ratio 0.6938 to 0.7341 |
pass |
|
|
control |
law SW at n = 4,000, the ATE, mechanism_law=’sample’: the reported standard errors are multiplied by a declared factor below one |
the SE-ratio interval must fall below the calibration band |
coverage 0.8124 to 0.8433, SE ratio 0.6812 to 0.7204 |
pass |
|
|
positive |
law LW at n = 4,000, the always-versus-never contrast, mechanism_law=’sample’ with every nuisance correct |
99% interval of the standardized bias inside the margin |
bias -0.0025 to 0.0030, margin 0.0167 |
pass |
|
|
positive |
law SW at n = 1,000, the ATE, mechanism_law=’sample’ with every nuisance correct |
99% interval of the standardized bias inside the margin |
bias -0.000736 to 0.0021, margin 0.0087 |
pass |
|
|
positive |
law SW at n = 16,000, the ATE, mechanism_law=’sample’ with every nuisance correct |
99% interval of the standardized bias inside the margin |
bias -0.000283 to 0.000408, margin 0.0021 |
pass |
|
|
positive |
law SW at n = 4,000, the ATE, mechanism_law=’sample’ with every nuisance correct |
99% interval of the standardized bias inside the margin |
bias -0.000656 to 0.000733, margin 0.0043 |
pass |
|
|
positive |
law LW at n = 4,000, the always-versus-never contrast, mechanism_law=’sample’ with an intercept-only regression at node one and the correct tilt classifier |
99% interval of the standardized bias inside the margin |
bias -0.0050 to 0.000690, margin 0.0173 |
pass |
|
|
positive |
law SW at n = 1,000, the ATE, mechanism_law=’sample’ with the main-terms outcome regression on (A, W1, W2) and the correct tilt classifier |
99% interval of the standardized bias inside the margin |
bias -0.000320 to 0.0027, margin 0.0092 |
pass |
|
|
positive |
law SW at n = 16,000, the ATE, mechanism_law=’sample’ with the main-terms outcome regression on (A, W1, W2) and the correct tilt classifier |
99% interval of the standardized bias inside the margin |
bias -0.000300 to 0.000447, margin 0.0023 |
pass |
|
|
positive |
law SW at n = 4,000, the ATE, mechanism_law=’sample’ with the main-terms outcome regression on (A, W1, W2) and the correct tilt classifier |
99% interval of the standardized bias inside the margin |
bias -0.000507 to 0.000974, margin 0.0045 |
pass |
|
|
control |
law LW at n = 4,000, the always-versus-never contrast, mechanism_law=’target’ (dividing by the declaration) with an intercept-only regression at node one |
99% interval of the standardized bias wholly outside the margin |
bias 0.4524 to 0.4579, margin 0.0167 |
pass |
|
|
control |
law SW at n = 1,000, the ATE, mechanism_law=’target’ (dividing by the declaration) with the main-terms outcome regression on (A, W1, W2) |
99% interval of the standardized bias wholly outside the margin |
bias -0.0336 to -0.0309, margin 0.0082 |
pass |
|
|
control |
law SW at n = 16,000, the ATE, mechanism_law=’target’ (dividing by the declaration) with the main-terms outcome regression on (A, W1, W2) |
99% interval of the standardized bias wholly outside the margin |
bias -0.0333 to -0.0326, margin 0.0021 |
pass |
|
|
control |
law SW at n = 4,000, the ATE, mechanism_law=’target’ (dividing by the declaration) with the main-terms outcome regression on (A, W1, W2) |
99% interval of the standardized bias wholly outside the margin |
bias -0.0336 to -0.0323, margin 0.0041 |
pass |
|
|
positive |
law SW at n = 4,000, the ATE, mechanism_law=’sample’ with the correct outcome regression and a tilt classifier on W2 alone |
99% interval of the standardized bias inside the margin |
bias -0.000819 to 0.000540, margin 0.0042 |
pass |
sample_misspecified is the direct witness of the tilt. With the outcome regression wrong,
only a correct tilted mechanism removes the bias, so a reverted tilt or a partial one shows
there as bias. Its interval over-covers on LW, because the curve omits the term for estimating
\(\hat g_w\), so its calibration is published and not gated. tilt_misspecified witnesses the
other half of the double robustness, and both_misspecified shows that its wrong classifier
drops a term that matters.
Each control row also publishes its exact-law bias and its paired difference: the control minus
the sample_misspecified cell of the same draws, in units of the control’s standard deviation.
The partner removes the whole control bias on the same draws.
Measured values and declared margins#
Names beginning margin: are thresholds declared before the run. Everything else is measured
from the committed results and checked at the precision printed.
quantity |
value |
source |
|---|---|---|
|
2000 |
primary replications |
|
4000 |
observations per primary replication |
|
3 |
truth tests passing |
|
3 |
truth tests reported |
|
26 |
property cells passing |
|
26 |
property cells reported |
|
0.0303 |
largest primary standardized bias |
|
0.9405 |
lowest primary coverage |
|
0.9934 |
SE ratio of the SW calibration cell at n = 1,000 |
|
1.0001 |
SE ratio of the SW calibration cell at n = 16,000 |
|
0.9926 |
SE ratio of the LW calibration cell |
|
0.9520 |
coverage of the LW calibration cell |
|
1.2144 |
SE ratio of the LW cell with the node-one regression wrong |
|
0.9312 |
SE ratio of the SW cell with the tilt classifier wrong |
|
-3.9599 |
standardized bias of the |
|
6.8119 |
standardized bias of the |
|
-2.0607 |
standardized bias of the both-wrong control |
|
0.9900 |
Monte Carlo confidence level |
|
0.2500 |
standardized-bias margin |
|
0.9000 |
primary coverage floor |
|
0.8000 |
primary SE-ratio lower screen |
|
1.2000 |
primary SE-ratio upper screen |
|
0.9300 |
calibration SE-ratio lower bound |
|
1.0700 |
calibration SE-ratio upper bound |
|
0.9200 |
calibration coverage lower bound |
|
0.9800 |
calibration coverage upper bound |
|
0.7000 |
negative-control SE multiplier |
|
0.0100 |
declared share of replications a cell may lose to a recordable fitting failure |
|
0.0500 |
test size |
|
0.9500 |
nominal interval coverage |
|
10000 |
bootstrap replications |
|
0.9900 |
descriptive overcoverage threshold |
|
20 |
the same bound, in primary replications |
|
0.1000 |
type-I upper bound. No cell of this study reads it |
|
0.8000 |
minimum power lower bound. No cell of this study reads it |
|
0.1500 |
paired similarity margin in pooled SDs. No cell of this study reads it |
|
1.1000 |
RMSE-ratio noninferiority bound. No cell of this study reads it |
|
-0.0250 |
coverage-difference noninferiority bound. No cell of this study reads it |
|
0.0500 |
calibration-excess noninferiority bound. No cell of this study reads it |
|
-0.5000 |
expected root-n slope. No cell of this study reads it |
|
-0.6250 |
root-n slope lower bound. No cell of this study reads it |
|
-0.3750 |
root-n slope upper bound. No cell of this study reads it |
|
-0.2500 |
slower rate the interval must exclude. No cell of this study reads it |
Limitations#
limit |
what it means for use |
|---|---|
parametric learners |
the evidence covers correct or misspecified logistic and linear learners. With a flexible learner the ordinary conditions of an estimated-mechanism TMLE apply, and no cell measures them |
a weight on the arm and the covariates |
no cell reads a weight that depends on the outcome, which also loses the causal reading under |
one node tilted on LW |
the LW weight tilts the first node only. A tilt at the second node shows here only through the SE ratio, and the fast tier’s exact-law tests cover it |
binary treatments with complete data |
more than two arms, a missing outcome, censoring and clusters rest on the exact-law tests alone |
not efficient for a known \(g_0\) |
the fit uses the declaration as an offset of the classifier and is not efficient in the model in which \(g_0\) is known |
no comparator |
no external implementation estimates the tilted mechanism from a declaration |
Reproduction#
Run python tests/canonical/known_sample_weights/regenerate.py --output DIR with an empty
scratch directory outside the repository to regenerate the artifacts. The pilot is
tests/studies/known_sample_weights_pilot.py, and the red-cell readings are declared in
tests/canonical/known_sample_weights/regenerate.py before any run.