Marginal sensitivity bound limit coverage#
This study measures the coverage of the confidence limits on each end of the marginal sensitivity
model bounds of X82 part H. The function marginal_sensitivity_bounds resolves each limit through
the evidence registry with the instrument msm_bound_limit and one rule. A passing cell adds one
registry row for the configuration it measured. The study reads each end of the ATE bound at
\(\Gamma = 1.5\) as an estimate of the population end of the law. It also reads the reported
standard error of that end.
No canonical implementation is compared. The authors’ code (Dorn, Guo and Kallus) is R and
fits grf forests, so it computes another estimator. The zero-row equivalence artifact records
the absence of a comparator.
What was tested#
setting |
declaration |
|---|---|
cells |
SH1 |
laws |
|
fit |
|
bounds |
|
primary estimands |
the lower and the upper end of the ATE bound at \(\Gamma = 1.5\), 4 rows |
primary interval |
the end plus or minus 1.959964 reported standard errors |
truth |
the population ATE bound of the law at \(\Gamma = 1.5\): the difference of the sharp arm-mean bounds, by tensor Gauss-Legendre quadrature. SH1 \([0.678, 1.322]\), SH2 \([0.0341, 0.2508]\) |
size |
2,000 replications at \(n = 8000\) per cell, and 6,800 property draws per cell |
Monte Carlo inference |
99% intervals around every declared endpoint |
X82-H-plan.md rev 2.5, section 8, in the plans repository fixed the cells, the size, the seeds,
the controls and the red-cell route before any run. Pilots on seeds outside the declared streams
sized the run.
Accuracy against known truth#
law |
estimand |
what was tested |
implementation |
bias (99% interval) |
coverage |
SE ratio |
result |
|---|---|---|---|---|---|---|---|
Gaussian linear outcome, 20 covariates, logistic propensity; GLMs |
|
lower end of the ATE bound under the marginal sensitivity model at Gamma 1.5 |
|
-0.0050 to -0.0022 |
0.9510 |
1.0211 |
pass |
Gaussian linear outcome, 20 covariates, logistic propensity; GLMs |
|
upper end of the ATE bound under the marginal sensitivity model at Gamma 1.5 |
|
0.0021 to 0.0049 |
0.9495 |
1.0259 |
pass |
logistic outcome, prevalence near 0.33, 20 covariates; GLMs |
|
lower end of the ATE bound under the marginal sensitivity model at Gamma 1.5 |
|
-0.0012 to 0.000059 |
0.9510 |
1.0039 |
pass |
logistic outcome, prevalence near 0.33, 20 covariates; GLMs |
|
upper end of the ATE bound under the marginal sensitivity model at Gamma 1.5 |
|
-0.000098 to 0.0011 |
0.9495 |
0.9925 |
pass |
An estimated quantile moves each end outward at second order. The bias is about 0.15 empirical standard deviations in SH1 and 0.05 in SH2. Both lie inside the 0.25 margin.
Theory properties#
Each scenario’s cells read the same 6,800 draws, and one fit per draw gives every row. A positive
cell must put its SE-ratio interval inside the calibration band and its coverage interval inside
the coverage band. Each row has two controls. The inflated_se_control multiplies the reported
standard error by 1.5, and its SE-ratio interval must rise above the band. The
wrong_gamma_control reads the end at \(\Gamma = 1.25\) against the \(\Gamma = 1.5\) truth, and its
coverage interval must fall below the band.
property |
cell |
role |
what was tested |
what must hold |
measured |
result |
|---|---|---|---|---|---|---|
|
|
positive |
lower end of the ATE bound under the marginal sensitivity model at Gamma 1.5: every nuisance is correctly specified, and the row reads its reported standard error |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9417 to 0.9556, SE ratio 0.9834 to 1.0248 |
pass |
|
|
control |
lower end of the ATE bound under the marginal sensitivity model at Gamma 1.5: the reported standard error is multiplied by 1.5 |
the SE-ratio interval must fall above the calibration band |
coverage 0.9951 to 0.9986, SE ratio 1.4723 to 1.5387 |
pass |
|
|
control |
lower end of the ATE bound under the marginal sensitivity model at Gamma 1.5: the end at Gamma 1.25, read against the Gamma 1.5 truth |
the coverage interval must fall below the calibration band |
coverage 0 to 0.000779, SE ratio 0.9834 to 1.0275 |
pass |
|
|
positive |
upper end of the ATE bound under the marginal sensitivity model at Gamma 1.5: every nuisance is correctly specified, and the row reads its reported standard error |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9466 to 0.9599, SE ratio 0.9904 to 1.0355 |
pass |
|
|
control |
upper end of the ATE bound under the marginal sensitivity model at Gamma 1.5: the reported standard error is multiplied by 1.5 |
the SE-ratio interval must fall above the calibration band |
coverage 0.9942 to 0.9980, SE ratio 1.4861 to 1.5514 |
pass |
|
|
control |
upper end of the ATE bound under the marginal sensitivity model at Gamma 1.5: the end at Gamma 1.25, read against the Gamma 1.5 truth |
the coverage interval must fall below the calibration band |
coverage 7.371e-07 to 0.0011, SE ratio 0.9881 to 1.0321 |
pass |
|
|
positive |
lower end of the ATE bound under the marginal sensitivity model at Gamma 1.5: every nuisance is correctly specified, and the row reads its reported standard error |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9488 to 0.9618, SE ratio 0.9907 to 1.0346 |
pass |
|
|
control |
lower end of the ATE bound under the marginal sensitivity model at Gamma 1.5: the reported standard error is multiplied by 1.5 |
the SE-ratio interval must fall above the calibration band |
coverage 0.9959 to 0.9990, SE ratio 1.4859 to 1.5525 |
pass |
|
|
control |
lower end of the ATE bound under the marginal sensitivity model at Gamma 1.5: the end at Gamma 1.25, read against the Gamma 1.5 truth |
the coverage interval must fall below the calibration band |
coverage 0.0013 to 0.0047, SE ratio 0.9902 to 1.0334 |
pass |
|
|
positive |
upper end of the ATE bound under the marginal sensitivity model at Gamma 1.5: every nuisance is correctly specified, and the row reads its reported standard error |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9461 to 0.9594, SE ratio 0.9925 to 1.0370 |
pass |
|
|
control |
upper end of the ATE bound under the marginal sensitivity model at Gamma 1.5: the reported standard error is multiplied by 1.5 |
the SE-ratio interval must fall above the calibration band |
coverage 0.9953 to 0.9987, SE ratio 1.4874 to 1.5563 |
pass |
|
|
control |
upper end of the ATE bound under the marginal sensitivity model at Gamma 1.5: the end at Gamma 1.25, read against the Gamma 1.5 truth |
the coverage interval must fall below the calibration band |
coverage 0.0039 to 0.0089, SE ratio 0.9918 to 1.0371 |
pass |
Result#
Every primary test and every property cell passed. The registry gains one msm_bound_limit row for
each rule.
rule |
covered configuration |
|---|---|
|
the |
|
the |
Both rows also require TMLE, five-fold cross-fitting, influence-curve inference, no declared
mechanism, two arms, one cross-fitting draw, \(n \ge 8000\), and at most 0.0025 adjustment columns
per row. The 875 floor lies between the minimum (827) and the 5th percentile (884) of the SH2
primary draws.
The set interval [lower - z se, upper + z se] covered the population set in 96.8% of the SH1 primary
draws and in 95.7% of the SH2 draws. This joint reading is descriptive.
Measured values#
Names beginning margin: are thresholds declared before the run. Everything else is measured
from the committed results and checked at the precision printed.
quantity |
value |
source |
|---|---|---|
|
2000 |
primary replications |
|
8000 |
observations per primary replication |
|
4 |
bound-end tests against truth |
|
4 |
of those, passing |
|
0 |
external comparisons declared |
|
0 |
external comparisons passing |
|
12 |
repeated-sampling property cells |
|
12 |
cells whose own and family verdicts pass |
|
0.1462 |
largest absolute primary bias in empirical standard deviations |
|
0.9495 |
lowest measured primary-study coverage |
|
0.9355 |
lowest exact 99% primary coverage endpoint |
|
0.9544 |
lowest bootstrap primary SE-ratio endpoint |
|
1.0715 |
highest bootstrap primary SE-ratio endpoint |
|
0.9900 |
confidence level of every Monte Carlo interval |
|
0.0500 |
nominal size of the reported intervals |
|
0.9500 |
nominal coverage those intervals claim |
|
10000 |
resamples behind every bootstrap interval |
|
0.2500 |
bias equivalence margin, in empirical standard deviations |
|
0.9000 |
validity floor the coverage lower endpoint must clear |
|
0.9900 |
above this, coverage is conservative rather than invalid |
|
0.8000 |
SE-ratio screen, lower limit |
|
1.2000 |
SE-ratio screen, upper limit |
|
0.9300 |
calibration-cell SE-ratio band, lower limit |
|
1.0700 |
calibration-cell SE-ratio band, upper limit. A control must rise above it |
|
0.9200 |
calibration-cell coverage band, lower limit |
|
0.9800 |
calibration-cell coverage band, upper limit |
|
0.1000 |
largest size a one-sided type-I bound may establish |
|
0.1500 |
paired similarity margin, in pooled empirical standard deviations |
|
1.1000 |
largest external-comparison RMSE ratio bound |
|
-0.0250 |
smallest external-comparison coverage difference bound |
|
0.0500 |
largest external-comparison calibration excess bound |
|
0.8000 |
rejection lower bound a power control must clear |
|
-0.5000 |
contraction rate root-n asymptotics predict |
|
-0.6250 |
accepted root-n slope band, lower limit |
|
-0.3750 |
accepted root-n slope band, upper limit |
|
-0.2500 |
slower rate a root-n interval must exclude |
|
0.0100 |
declared share of replications a cell may lose to a recordable fitting failure |
|
20 |
the same bound, in primary replications |
Limitations#
limitation |
what it means for use |
|---|---|
There is no cross-implementation evidence |
No maintained Python implementation computes these bounds. The R code of the authors fits other learners |
One law, size and learner per rule |
A fit outside the covered configuration prints the descriptive sentence and names the covered one |
The |
The arm means, |
The default quantile and tail learners only |
A caller learner reads |
One cross-fitting draw |
A fit with |
No sharpness claim for the ATE set |
The arm-mean ends are sharp. The ATE set is their difference, and the page claims coverage of that set only |
Reproduction#
The fixture README
gives the regeneration command. The
manifest
records the seeds, margins, exact estimator configuration, source hashes, and result hashes.
cells.csv records the fit configuration of each row.