Band-rank placebo verdict rule#

This study calibrates the placebo t rule that cleverly.refute prints on a continuous dose whose declared support is a function. On such a dose the placebo draws each dose’s position inside its band, then maps the position into the receiving unit’s band. The band-rank placebo paragraph of the validation reference defines the draw.

rule

reading

rejects when

placebo t

20 band-rank placebo refits against the exact null, t with 19 degrees of freedom

the two-sided p-value is below 0.05

The study asks two questions for each configuration. Is the rule grossly miscalibrated under its null? Does the rule detect a declared defect? A rule that passes both checks prints a verdict on a fit inside the calibrated scope. On any other fit, the rule prints its numbers and no verdict.

No canonical implementation is compared. No maintained implementation computes this rule. The zero-row equivalence artifact records the absence of a comparator.

What was tested#

setting

declaration

sample

\(n = 2000\) units, one fit per trial, five-fold cross-fitting, 20 placebo refits per reading

law P

\(W_1, W_2 \sim U(-1, 1)\). The dose band is \([L, U]\) with \(L = W_1 + 0.5 W_2\) and \(U - L = 2 + 0.75 W_1\). The position \(u = (A - L) / (U - L)\) is a normal with mean \(0.5 + 0.2 W_2\) and SD 0.25, truncated to \([0, 1]\). \(Y = A + 0.8 W_1 + 0.6 W_2 + e\), with \(e \sim N(0, 1)\)

law L

the shape of the make_sequential_pricing law: three nodes, a binary engagement \(L_t\) and a price \(A_t\). The band at node \(t\) has the lower end \(2 + L_t + 0.5 A_{t-1}\) and the width \(2 + L_t\). The position follows a truncated normal with SD 0.4 that reads \(W\) and the earlier position. The outcome is binary

cell PJ1

TMLE of the policy up against the natural course on law P. up adds 0.5 to the dose where the result stays in the band. An OLS outcome and a classifier density ratio with a quadratic logistic. The draw is band_permute

cell LJ1

LTMLE of the regimen up against the natural course on law L. up adds 0.25 to each price where the result stays in the band. Logistic GLM outcome and pseudo-outcome regressions, and the same classifier ratio. The draw is band_markov

size cells

200 trials per cell. A cell passes at no more than 20 rejections

power cells

trials 0 to 49 of the size cell under a stale-row placebo. A cell passes at no fewer than 38 detections

defect

a declared share of units keeps its own dose (PJ1, 0.10) or its whole observed trajectory (LJ1, 0.15). The other units keep their band-rank draws

primary phase

200 replications of the PJ1 contrast against its exact truth, as a sanity check of the fit that the rule reads

Monte Carlo inference

exact 99% intervals around every rate, and 99% intervals around every primary endpoint

X82-J-plan.md rev 2 fixed the laws, the cells, the seeds and the red-cell route before the run. The design review set the size cutoff to 20, because the 20 refits of one PJ1 trial share one remainder of the OLS outcome. The module docstring of tests/studies/refuter_calibration_band.py states each law and the defect. tests/unit/test_refuter_calibration_band_design.py reads the sizing probe in tests/diagnostics/x82_sj_sizing/.

quantity

PJ1

LJ1

placebo bias, in placebo SD

-0.031

0.000

stale-row shift, in placebo SD

1.51

1.02

probe trials

100

60

A size cell with 200 trials checks gross miscalibration only. A rule with true size 0.05 passes with probability 0.999, and a rule with true size 0.15 passes with probability 0.025. A power cell with 50 trials passes with probability 1.000 at true power 0.95. It passes with probability 0.814 at true power 0.80.

Accuracy against known truth#

The primary phase checks the fit that the rule reads. It does not calibrate the rule.

law

estimand

what was tested

implementation

bias (99% interval)

coverage

SE ratio

result

law P: a continuous dose in a band [L(W), U(W)] whose location and width read W; TMLE of a capped +0.5 shift at five folds

ate

average treatment effect

cleverly fit that the band-rank placebo rule reads

-0.0024 to 0.0078

0.9550

1.0145

fail

Theory properties#

A refuter_size cell counts the rejections of the rule under its null. A refuter_power cell counts the detections of the stale-row defect on the first 50 trials of the same configuration. The cell name gives the configuration, then the reading.

property

cell

role

what was tested

what must hold

measured

result

refuter_power

LJ1__placebo_stale_rows

control

LTMLE of a dose shift at three nodes on the pricing-shaped law L: the placebo t rule, with a declared share of stale rows

at least 38 detections in 50 trials

detections 49 of 50

pass

refuter_power

PJ1__placebo_stale_rows

control

TMLE of a capped dose shift on law P: the placebo t rule, with a declared share of stale rows

at least 38 detections in 50 trials

detections 50 of 50

pass

refuter_size

LJ1__placebo

positive

LTMLE of a dose shift at three nodes on the pricing-shaped law L: the placebo t rule against the exact band-rank null

no more than 20 rejections in 200 trials

rejections 11 of 200

pass

refuter_size

PJ1__placebo

positive

TMLE of a capped dose shift on law P: the placebo t rule against the exact band-rank null

no more than 20 rejections in 200 trials

rejections 10 of 200

pass

Result#

All four property cells pass. The size cells reject in 10 (PJ1) and 11 (LJ1) of 200 trials, below the limit of 20. The power cells detect the defect in 50 (PJ1) and 49 (LJ1) of 50 trials, above the floor of 38. The registry VERDICT_EVIDENCE therefore holds one placebo row for each cell. Each row’s scope is the configuration that its cells recorded in cells.csv.

tests/unit/test_refuter_calibration_band_registry.py checks each scope against the passing cells of the committed run.

The primary truth row is red on its bias leg. The primary phase has 200 replications, which cannot resolve its bias margin. The bias interval, -0.0024 to 0.0078 in outcome units, contains 0 and crosses the margin of 0.0070 in the same units. The coverage limit is 0.9027, above the floor of 0.90, and the SE-ratio interval contains 1. The red-cell ledger names the owner.

Measured values#

Names beginning margin: are thresholds declared before the run. Everything else is measured from the committed results and checked at the precision printed.

quantity

value

source

replicates

200

primary replications

n

2000

observations per primary replication

independent_tests_total

1

primary tests against truth

independent_tests_passed

0

of those, passing

paired_tests_total

0

external comparisons declared

paired_tests_passed

0

external comparisons passing

property_cells_total

4

repeated-sampling property cells

property_cells_passed

4

cells whose own and family verdicts pass

max_standardized_bias

0.0978

largest absolute primary bias in empirical standard deviations

min_coverage

0.9550

lowest measured primary-study coverage

min_se_ratio_ci_lower

0.9052

lowest bootstrap primary SE-ratio endpoint

max_se_ratio_ci_upper

1.1631

highest bootstrap primary SE-ratio endpoint

margin:confidence_level

0.9900

confidence level of every Monte Carlo interval

margin:alpha

0.0500

nominal size of the reported intervals, and the level of the rule

margin:nominal_coverage

0.9500

nominal coverage those intervals claim

margin:bootstrap_replicates

10000

resamples behind every bootstrap interval

margin:type_i_ceiling

0.1000

the rate a type-I cell must bound. No cell of this study reads it; a size cell reads its count

margin:minimum_power

0.8000

rejection lower bound a power family must clear. No cell of this study reads it; a power cell reads its count

margin:standardized_bias

0.2500

bias equivalence margin, in empirical standard deviations

margin:coverage_floor

0.9000

validity floor the coverage lower endpoint must clear

margin:over_coverage_ceiling

0.9900

above this, coverage is conservative rather than invalid

margin:se_ratio_sanity_lower

0.8000

SE-ratio screen, lower limit

margin:se_ratio_sanity_upper

1.2000

SE-ratio screen, upper limit

margin:calibration_se_ratio_lower

0.9300

calibration-cell SE-ratio band, lower limit. No cell of this study reads it

margin:calibration_se_ratio_upper

1.0700

calibration-cell SE-ratio band, upper limit. No cell of this study reads it

margin:calibration_coverage_lower

0.9200

calibration-cell coverage band, lower limit. No cell of this study reads it

margin:calibration_coverage_upper

0.9800

calibration-cell coverage band, upper limit. No cell of this study reads it

margin:paired_difference

0.1500

paired similarity margin, in pooled empirical standard deviations

margin:rmse_noninferiority

1.1000

largest external-comparison RMSE ratio bound

margin:coverage_noninferiority

-0.0250

smallest external-comparison coverage difference bound

margin:calibration_noninferiority

0.0500

largest external-comparison calibration excess bound

margin:root_n_slope

-0.5000

contraction rate root-n asymptotics predict

margin:root_n_slope_lower

-0.6250

accepted root-n slope band, lower limit

margin:root_n_slope_upper

-0.3750

accepted root-n slope band, upper limit

margin:excluded_slope

-0.2500

slower rate a root-n interval must exclude

margin:subject_failure_bound

0.0100

declared share of replications a cell may lose to a recordable fitting failure

margin:subject_failures_allowed

2

the same bound, in primary replications

Limitations#

limitation

what it means for use

The row publishes under the reporting policy, not gated

The fast tier recomputes each verdict and does not fail on a red one

There is no cross-implementation evidence

No maintained implementation computes this rule

Gross miscalibration only

A rule with true size 0.10 passes a size cell with probability 0.559. The check does not certify the size to two decimals

One law and one size per cell

Each row covers \(n \ge 2000\) at the cell’s covariates per row. A smaller fit prints no verdict

The study estimand and node count only

The PJ1 row covers the recorded parameter ate_policy[up vs natural course], as the SG policy rows do. A policy with another name prints no verdict. The LJ1 row covers the recorded stem ate_regimen, because a longitudinal fit records the stem. It therefore covers any regimen contrast at three nodes with the study learners. A fit with another fold count or node count prints no verdict

The study learners only

Both rows name the fingerprint of QuadraticLogistic, a learner class of the study module in tests/studies. A user fit gets a verdict only through a learner with that exact fingerprint. In practice a banded user fit stays descriptive

The classifier ratio only

ratio="density" ran in no cell, so that reading stays descriptive

The stale-row power is approximate

The probe sizes the population shift of the placebo. The shift of one trial varies about it. LJ1’s stale-row cell detected 49 of 50

The primary phase is under-resolved

200 replications cannot put the 99% bias interval inside its margin. The truth row is red with an owner, and no rule row reads it

Reproduction#

The fixture README gives the regeneration command. The manifest records the seeds, the margins, the laws, the source hashes and the result hashes. The cell configurations and the property results carry every published row.