E-value limit coverage#
This study measures the coverage of the risk-ratio intervals that two part G E-value limits map.
An E-value limit is a monotone map of its risk-ratio limit, so the coverage of that interval is the
claim. Each part G configuration resolves its limit through the evidence registry with the
instrument evalue_limit and one rule. A passing cell adds one registry row for the configuration
it measured.
No canonical implementation is compared. The zero-row equivalence artifact records the absence of a comparator.
What was tested#
setting |
declaration |
|---|---|
cells |
E3 |
E3 law and fit |
|
E4 law and fit |
the |
primary estimands |
E3 |
primary interval |
the reported interval, on the log scale |
size |
1,600 replications at \(n = 2000\) per cell, and 4,000 property draws per cell |
Monte Carlo inference |
99% intervals around every declared endpoint |
X82-SG-plan.md rev 2 in the plans repository fixed the cells, the budget, the seeds and the
red-cell route before any run.
Accuracy against known truth#
law |
estimand |
what was tested |
implementation |
bias (99% interval) |
coverage |
SE ratio |
result |
|---|---|---|---|---|---|---|---|
|
|
marginal risk ratio, reported on the log scale, in stratum V=0 |
|
-0.0036 to 0.0043 |
0.9575 |
1.0381 |
pass |
|
|
marginal risk ratio, reported on the log scale, in stratum V=1 |
|
-0.0028 to 0.0035 |
0.9487 |
0.9863 |
pass |
|
|
marginal risk ratio, reported on the log scale, in stratum V=2 |
|
-0.000099 to 0.0044 |
0.9469 |
1.0074 |
pass |
the |
|
ratio of the arm-1 and arm-0 risks at t = 5, on the log scale |
|
-0.000826 to 0.0057 |
0.9619 |
1.0247 |
pass |
Theory properties#
Each scenario’s cells read the same 4,000 draws. A positive cell must put its SE-ratio interval
inside the calibration band and its coverage interval inside the coverage band. Each row also has
an inflated_se_control, which multiplies the reported standard error by 1.5. Its SE-ratio
interval must rise above the band.
property |
cell |
role |
what was tested |
what must hold |
measured |
result |
|---|---|---|---|---|---|---|
|
|
positive |
risk ratio in stratum V=0, on the log scale: every nuisance is correctly specified, and the row reads its reported limit |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9442 to 0.9617, SE ratio 0.9762 to 1.0349 |
pass |
|
|
control |
risk ratio in stratum V=0, on the log scale: the reported standard error is multiplied by 1.5 |
the SE-ratio interval must fall above the calibration band |
coverage 0.9923 to 0.9979, SE ratio 1.4624 to 1.5538 |
pass |
|
|
positive |
risk ratio in stratum V=1, on the log scale: every nuisance is correctly specified, and the row reads its reported limit |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9456 to 0.9628, SE ratio 0.9871 to 1.0428 |
pass |
|
|
control |
risk ratio in stratum V=1, on the log scale: the reported standard error is multiplied by 1.5 |
the SE-ratio interval must fall above the calibration band |
coverage 0.9950 to 0.9992, SE ratio 1.4796 to 1.5658 |
pass |
|
|
positive |
risk ratio in stratum V=2, on the log scale: every nuisance is correctly specified, and the row reads its reported limit |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9511 to 0.9673, SE ratio 0.9872 to 1.0451 |
pass |
|
|
control |
risk ratio in stratum V=2, on the log scale: the reported standard error is multiplied by 1.5 |
the SE-ratio interval must fall above the calibration band |
coverage 0.9943 to 0.9989, SE ratio 1.4795 to 1.5670 |
pass |
|
|
positive |
ratio of the arm-1 and arm-0 risks at t = 5, on the log scale: every nuisance is correctly specified, and the row reads its reported limit |
SE ratio and coverage intervals both inside their calibration bands |
coverage 0.9367 to 0.9553, SE ratio 0.9703 to 1.0286 |
pass |
|
|
control |
ratio of the arm-1 and arm-0 risks at t = 5, on the log scale: the reported standard error is multiplied by 1.5 |
the SE-ratio interval must fall above the calibration band |
coverage 0.9933 to 0.9984, SE ratio 1.4551 to 1.5435 |
pass |
Result#
Every primary test and every property cell passed. The registry gains two evalue_limit rows.
rule |
covered configuration |
|---|---|
|
|
|
the ratio of two static regimen risks of an in-sample hazard LTMLE with five nodes, unpenalized logistic hazards, two arms, a smallest event count of 100 |
Both rows also require influence-curve inference, no declared mechanism, \(n \ge 2000\), and at most 0.001 adjustment columns per row.
Measured values#
Names beginning margin: are thresholds declared before the run. Everything else is measured
from the committed results and checked at the precision printed.
quantity |
value |
source |
|---|---|---|
|
1600 |
primary replications |
|
2000 |
observations per primary replication |
|
4 |
bound-end tests against truth |
|
4 |
of those, passing |
|
0 |
external comparisons declared |
|
0 |
external comparisons passing |
|
8 |
repeated-sampling property cells |
|
8 |
cells whose own and family verdicts pass |
|
0.0616 |
largest absolute primary bias in empirical standard deviations |
|
0.9469 |
lowest measured primary-study coverage |
|
0.9307 |
lowest exact 99% primary coverage endpoint |
|
0.9443 |
lowest bootstrap primary SE-ratio endpoint |
|
1.0899 |
highest bootstrap primary SE-ratio endpoint |
|
0.9900 |
confidence level of every Monte Carlo interval |
|
0.0500 |
nominal size of the reported intervals |
|
0.9500 |
nominal coverage those intervals claim |
|
10000 |
resamples behind every bootstrap interval |
|
0.2500 |
bias equivalence margin, in empirical standard deviations |
|
0.9000 |
validity floor the coverage lower endpoint must clear |
|
0.9900 |
above this, coverage is conservative rather than invalid |
|
0.8000 |
SE-ratio screen, lower limit |
|
1.2000 |
SE-ratio screen, upper limit |
|
0.9300 |
calibration-cell SE-ratio band, lower limit |
|
1.0700 |
calibration-cell SE-ratio band, upper limit. A control must rise above it |
|
0.9200 |
calibration-cell coverage band, lower limit |
|
0.9800 |
calibration-cell coverage band, upper limit |
|
0.1000 |
largest size a one-sided type-I bound may establish |
|
0.1500 |
paired similarity margin, in pooled empirical standard deviations |
|
1.1000 |
largest external-comparison RMSE ratio bound |
|
-0.0250 |
smallest external-comparison coverage difference bound |
|
0.0500 |
largest external-comparison calibration excess bound |
|
0.8000 |
rejection lower bound a power control must clear |
|
-0.5000 |
contraction rate root-n asymptotics predict |
|
-0.6250 |
accepted root-n slope band, lower limit |
|
-0.3750 |
accepted root-n slope band, upper limit |
|
-0.2500 |
slower rate a root-n interval must exclude |
|
0.0100 |
declared share of replications a cell may lose to a recordable fitting failure |
|
16 |
the same bound, in primary replications |
Limitations#
limitation |
what it means for use |
|---|---|
There is no cross-implementation evidence |
No maintained implementation reports these limits |
One law, size and learner per rule |
A fit outside the covered configuration prints the descriptive sentence and names the covered one |
The |
The |
|
Those limits stay descriptive ( |
Reproduction#
The fixture README
gives the regeneration command. The
manifest
records the seeds, margins, exact estimator configuration, source hashes, and result hashes.
cells.csv records the fit configuration of each row.