Stopping rules on point TMLE#

This study validates the interval of point TMLE under stopping="scaled_var" and stopping="sample_size", each on the Newton walk (targeting="iterative") and on the one-step walk. The stopping rules section states the rules. Under either rule the walk can stop before the score equation is solved, and the estimate then carries the remaining score \(r_n\) as a first-order term. The reported interval adds it to the half-width, \(\psi_n \pm (z\,\widehat{se} + |r_n|)\), which covers whenever the plain Wald pivot does, whatever the residual’s dependence on the error. The widened interval is therefore conservative by construction, and the study measures how close to nominal it stays.

No package widens a Wald interval by its remaining score, so no canonical implementation is compared. The study rests on exact truths and on repeated-sampling properties.

What was fitted#

law

construction

fits

L1

the canonical-tmle binary and continuous laws, with that study’s logistic (binary) or linear (continuous) outcome GLM and logistic treatment GLM

each rule on each walk, in sample, at n = 2,000; the ATE and the arm means

L2

\(W_1, W_2 \sim N(0, 1)\), \(A \sim \operatorname{Bern}(\operatorname{expit}(0.4 W_1 - 0.3 W_2))\), \(Y = 4 W_1 + 0.5 W_2 + 0.1 A + N(0, 1)\), with correct linear and logistic GLMs

the one-step walk under each rule; the ATE and the mean under treatment, plain and widened

LN

\(V = W_1^2 - 1\) confounds treatment and outcome, \(Y = W_1 + 0.5 W_2 + V + 0.1 A + 3 N(0, 1)\); the outcome regression omits \(V\), so the initial score has a fixed sign

the one-step scaled_var walk with every threshold times 8, times 1, and under the relative rule; the mean under treatment

Every fit uses max_iter=100 (200 for the one-step walk), tol=1e-10 and canonical-tmle’s g_bounds. The laws, learners and the threshold scale are in tests/studies/_option_stopping_laws.py, and tests/unit/test_option_stopping_point_design.py recomputes every truth and declared number. The fast-tier witnesses in tests/unit/test_rule_widened_interval.py check the widened interval, the p-value and every consumer that reads it, each with a mutation that drops the residual.

The committed rows record the identity interval. The package now builds the interval of an unclustered mean of a binary outcome on the logit scale (small-sample scale), and the residual enters there as \(\lvert r_n\rvert / (\psi_n(1 - \psi_n))\). The ATE cells read a difference, whose interval is unchanged. On the same committed estimates, standard errors and residuals, the binary arm-mean row covers 0.9603 against the recorded 0.9606, and no cell changes its verdict (tests/canonical/interval-audit-screen.csv).

Accuracy against known truth#

law

estimand

what was tested

implementation

bias (99% interval)

coverage

SE ratio

result

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE and the mean under treatment; stopping=’scaled_var’ on the one-step walk, the widened interval

ate

average treatment effect

cleverly

-0.000995 to 0.000915

0.9594

1.0068

pass

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE and the mean under treatment; stopping=’scaled_var’ on the one-step walk, the widened interval

ey1

counterfactual mean under treatment

cleverly

-0.000371 to 0.0010

0.9606

1.0119

pass

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE and the mean under treatment; stopping=’scaled_var’ on the one-step walk, the widened interval

ate

average treatment effect

cleverly

0.000095 to 0.000523

0.9547

0.9963

pass

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE and the mean under treatment; stopping=’scaled_var’ on the one-step walk, the widened interval

ey1

counterfactual mean under treatment

cleverly

0.000127 to 0.000657

0.9578

1.0008

pass

Theory properties#

property

cell

role

what was tested

what must hold

measured

result

contrast_residual

l2_ss_one_step_ate__plain

diagnostic

law L2 (Y = 4 W1 + 0.5 W2 + 0.1 A + noise, correct linear and logistic GLMs), the ATE, n = 2,000: stopping=’sample_size’ on the one-step walk: the plain interval

none. The row is a diagnostic and states no verdict

coverage 0.9422 to 0.9513, SE ratio 0.9910, mean absolute residual 0.0039 SE

reported

contrast_residual

l2_ss_one_step_ate__widened

diagnostic

law L2 (Y = 4 W1 + 0.5 W2 + 0.1 A + noise, correct linear and logistic GLMs), the ATE, n = 2,000: stopping=’sample_size’ on the one-step walk: the widened interval

none. The row is a diagnostic and states no verdict

coverage 0.9429 to 0.9519, SE ratio 0.9910, mean absolute residual 0.0039 SE

reported

contrast_residual

l2_ss_one_step_ey1__plain

diagnostic

law L2 (Y = 4 W1 + 0.5 W2 + 0.1 A + noise, correct linear and logistic GLMs), the mean under treatment, n = 2,000: stopping=’sample_size’ on the one-step walk: the plain interval

none. The row is a diagnostic and states no verdict

coverage 0.9428 to 0.9518, SE ratio 0.9882, mean absolute residual 0.0018 SE

reported

contrast_residual

l2_ss_one_step_ey1__widened

diagnostic

law L2 (Y = 4 W1 + 0.5 W2 + 0.1 A + noise, correct linear and logistic GLMs), the mean under treatment, n = 2,000: stopping=’sample_size’ on the one-step walk: the widened interval

none. The row is a diagnostic and states no verdict

coverage 0.9431 to 0.9521, SE ratio 0.9882, mean absolute residual 0.0018 SE

reported

contrast_residual

l2_sv_one_step_ate__plain

diagnostic

law L2 (Y = 4 W1 + 0.5 W2 + 0.1 A + noise, correct linear and logistic GLMs), the ATE, n = 2,000: stopping=’scaled_var’ on the one-step walk: the plain interval

none. The row is a diagnostic and states no verdict

coverage 0.9437 to 0.9526, SE ratio 0.9946, mean absolute residual 0.0634 SE

reported

contrast_residual

l2_sv_one_step_ate__widened

diagnostic

law L2 (Y = 4 W1 + 0.5 W2 + 0.1 A + noise, correct linear and logistic GLMs), the ATE, n = 2,000: stopping=’scaled_var’ on the one-step walk: the widened interval

none. The row is a diagnostic and states no verdict

coverage 0.9505 to 0.9589, SE ratio 0.9946, mean absolute residual 0.0634 SE

reported

contrast_residual

l2_sv_one_step_ey1__plain

diagnostic

law L2 (Y = 4 W1 + 0.5 W2 + 0.1 A + noise, correct linear and logistic GLMs), the mean under treatment, n = 2,000: stopping=’scaled_var’ on the one-step walk: the plain interval

none. The row is a diagnostic and states no verdict

coverage 0.9426 to 0.9517, SE ratio 0.9902, mean absolute residual 0.0432 SE

reported

contrast_residual

l2_sv_one_step_ey1__widened

diagnostic

law L2 (Y = 4 W1 + 0.5 W2 + 0.1 A + noise, correct linear and logistic GLMs), the mean under treatment, n = 2,000: stopping=’scaled_var’ on the one-step walk: the widened interval

none. The row is a diagnostic and states no verdict

coverage 0.9471 to 0.9558, SE ratio 0.9902, mean absolute residual 0.0432 SE

reported

interval_calibration

binary_ss_newton__noise_control

control

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the Newton walk: a declared scale of independent noise is added to each estimate

the SE-ratio interval must fall below the calibration band

coverage 0.8211 to 0.8364, SE ratio 0.6931 to 0.7133

pass

interval_calibration

binary_ss_newton__shrunken_se_control

control

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the Newton walk: the reported standard errors are multiplied by a declared factor below one

the SE-ratio interval must fall below the calibration band

coverage 0.8242 to 0.8393, SE ratio 0.6917 to 0.7118

pass

interval_calibration

binary_ss_newton__widened

positive

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the Newton walk: the interval adds the remaining score to its half-width

SE ratio and coverage intervals both inside their calibration bands

coverage 0.9444 to 0.9533, SE ratio 0.9884 to 1.0172

pass

interval_calibration

binary_ss_one_step__noise_control

control

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the one-step walk: a declared scale of independent noise is added to each estimate

the SE-ratio interval must fall below the calibration band

coverage 0.8230 to 0.8381, SE ratio 0.6913 to 0.7109

pass

interval_calibration

binary_ss_one_step__shrunken_se_control

control

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the one-step walk: the reported standard errors are multiplied by a declared factor below one

the SE-ratio interval must fall below the calibration band

coverage 0.8246 to 0.8397, SE ratio 0.6921 to 0.7129

pass

interval_calibration

binary_ss_one_step__widened

positive

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the one-step walk: the interval adds the remaining score to its half-width

SE ratio and coverage intervals both inside their calibration bands

coverage 0.9454 to 0.9542, SE ratio 0.9890 to 1.0173

pass

interval_calibration

binary_sv_newton__noise_control

control

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the Newton walk: a declared scale of independent noise is added to each estimate

the SE-ratio interval must fall below the calibration band

coverage 0.8243 to 0.8394, SE ratio 0.6960 to 0.7159

pass

interval_calibration

binary_sv_newton__shrunken_se_control

control

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the Newton walk: the reported standard errors are multiplied by a declared factor below one

the SE-ratio interval must fall below the calibration band

coverage 0.8242 to 0.8393, SE ratio 0.6921 to 0.7123

pass

interval_calibration

binary_sv_newton__widened

positive

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the Newton walk: the interval adds the remaining score to its half-width

SE ratio and coverage intervals both inside their calibration bands

coverage 0.9444 to 0.9533, SE ratio 0.9883 to 1.0173

pass

interval_calibration

binary_sv_one_step__noise_control

control

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the one-step walk: a declared scale of independent noise is added to each estimate

the SE-ratio interval must fall below the calibration band

coverage 0.8267 to 0.8417, SE ratio 0.6963 to 0.7164

pass

interval_calibration

binary_sv_one_step__shrunken_se_control

control

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the one-step walk: the reported standard errors are multiplied by a declared factor below one

the SE-ratio interval must fall below the calibration band

coverage 0.8242 to 0.8393, SE ratio 0.6932 to 0.7137

pass

interval_calibration

binary_sv_one_step__widened

positive

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the one-step walk: the interval adds the remaining score to its half-width

SE ratio and coverage intervals both inside their calibration bands

coverage 0.9496 to 0.9581, SE ratio 0.9904 to 1.0189

pass

interval_calibration

continuous_ss_newton__noise_control

control

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the Newton walk: a declared scale of independent noise is added to each estimate

the SE-ratio interval must fall below the calibration band

coverage 0.8278 to 0.8428, SE ratio 0.6986 to 0.7190

pass

interval_calibration

continuous_ss_newton__shrunken_se_control

control

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the Newton walk: the reported standard errors are multiplied by a declared factor below one

the SE-ratio interval must fall below the calibration band

coverage 0.8228 to 0.8379, SE ratio 0.6925 to 0.7119

pass

interval_calibration

continuous_ss_newton__widened

positive

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the Newton walk: the interval adds the remaining score to its half-width

SE ratio and coverage intervals both inside their calibration bands

coverage 0.9474 to 0.9561, SE ratio 0.9898 to 1.0175

pass

interval_calibration

continuous_ss_one_step__noise_control

control

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the one-step walk: a declared scale of independent noise is added to each estimate

the SE-ratio interval must fall below the calibration band

coverage 0.8250 to 0.8401, SE ratio 0.7006 to 0.7203

pass

interval_calibration

continuous_ss_one_step__shrunken_se_control

control

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the one-step walk: the reported standard errors are multiplied by a declared factor below one

the SE-ratio interval must fall below the calibration band

coverage 0.8223 to 0.8374, SE ratio 0.6920 to 0.7119

pass

interval_calibration

continuous_ss_one_step__widened

positive

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the one-step walk: the interval adds the remaining score to its half-width

SE ratio and coverage intervals both inside their calibration bands

coverage 0.9496 to 0.9581, SE ratio 0.9889 to 1.0171

pass

interval_calibration

continuous_sv_newton__noise_control

control

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the Newton walk: a declared scale of independent noise is added to each estimate

the SE-ratio interval must fall below the calibration band

coverage 0.8265 to 0.8415, SE ratio 0.7012 to 0.7210

pass

interval_calibration

continuous_sv_newton__shrunken_se_control

control

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the Newton walk: the reported standard errors are multiplied by a declared factor below one

the SE-ratio interval must fall below the calibration band

coverage 0.8228 to 0.8379, SE ratio 0.6926 to 0.7118

pass

interval_calibration

continuous_sv_newton__widened

positive

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the Newton walk: the interval adds the remaining score to its half-width

SE ratio and coverage intervals both inside their calibration bands

coverage 0.9474 to 0.9561, SE ratio 0.9894 to 1.0176

pass

interval_calibration

continuous_sv_one_step__noise_control

control

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the one-step walk: a declared scale of independent noise is added to each estimate

the SE-ratio interval must fall below the calibration band

coverage 0.8289 to 0.8438, SE ratio 0.7009 to 0.7210

pass

interval_calibration

continuous_sv_one_step__shrunken_se_control

control

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the one-step walk: the reported standard errors are multiplied by a declared factor below one

the SE-ratio interval must fall below the calibration band

coverage 0.8218 to 0.8370, SE ratio 0.6926 to 0.7123

pass

interval_calibration

continuous_sv_one_step__widened

positive

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the one-step walk: the interval adds the remaining score to its half-width

SE ratio and coverage intervals both inside their calibration bands

coverage 0.9531 to 0.9613, SE ratio 0.9896 to 1.0180

pass

necessity_reference

ln_ey1_k1__plain

diagnostic

law LN (the outcome regression omits the confounding term V, so the initial score has a fixed sign), the mean under treatment, n = 2,000: one-step stopping=’scaled_var’ at the declared thresholds: the plain interval

none. The row is a diagnostic and states no verdict

coverage 0.9505 to 0.9589, SE ratio 1.0181, mean absolute residual 0.0595 SE

reported

necessity_reference

ln_ey1_k1__widened

diagnostic

law LN (the outcome regression omits the confounding term V, so the initial score has a fixed sign), the mean under treatment, n = 2,000: one-step stopping=’scaled_var’ at the declared thresholds: the widened interval

none. The row is a diagnostic and states no verdict

coverage 0.9562 to 0.9641, SE ratio 1.0181, mean absolute residual 0.0595 SE

reported

necessity_reference

ln_ey1_rel__widened

diagnostic

law LN (the outcome regression omits the confounding term V, so the initial score has a fixed sign), the mean under treatment, n = 2,000: one-step stopping=’relative’: the widened interval

none. The row is a diagnostic and states no verdict

coverage 0.9506 to 0.9590, SE ratio 1.0193, mean absolute residual 4.903e-09 SE

reported

plain_interval

binary_ss_newton__plain

diagnostic

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the Newton walk: the plain Wald interval of the same fits, without the residual

none. The row is a diagnostic and states no verdict

coverage 0.9444 to 0.9533, SE ratio 1.0025, mean absolute residual 5.195e-12 SE

reported

plain_interval

binary_ss_one_step__plain

diagnostic

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the one-step walk: the plain Wald interval of the same fits, without the residual

none. The row is a diagnostic and states no verdict

coverage 0.9444 to 0.9533, SE ratio 1.0031, mean absolute residual 0.0085 SE

reported

plain_interval

binary_sv_newton__plain

diagnostic

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the Newton walk: the plain Wald interval of the same fits, without the residual

none. The row is a diagnostic and states no verdict

coverage 0.9444 to 0.9533, SE ratio 1.0025, mean absolute residual 5.195e-12 SE

reported

plain_interval

binary_sv_one_step__plain

diagnostic

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the one-step walk: the plain Wald interval of the same fits, without the residual

none. The row is a diagnostic and states no verdict

coverage 0.9439 to 0.9529, SE ratio 1.0043, mean absolute residual 0.0417 SE

reported

plain_interval

continuous_ss_newton__plain

diagnostic

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the Newton walk: the plain Wald interval of the same fits, without the residual

none. The row is a diagnostic and states no verdict

coverage 0.9474 to 0.9561, SE ratio 1.0032, mean absolute residual 0.000008 SE

reported

plain_interval

continuous_ss_one_step__plain

diagnostic

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the one-step walk: the plain Wald interval of the same fits, without the residual

none. The row is a diagnostic and states no verdict

coverage 0.9467 to 0.9554, SE ratio 1.0029, mean absolute residual 0.0256 SE

reported

plain_interval

continuous_sv_newton__plain

diagnostic

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the Newton walk: the plain Wald interval of the same fits, without the residual

none. The row is a diagnostic and states no verdict

coverage 0.9474 to 0.9561, SE ratio 1.0032, mean absolute residual 0.000008 SE

reported

plain_interval

continuous_sv_one_step__plain

diagnostic

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the one-step walk: the plain Wald interval of the same fits, without the residual

none. The row is a diagnostic and states no verdict

coverage 0.9472 to 0.9559, SE ratio 1.0036, mean absolute residual 0.0537 SE

reported

relative_reference

binary_rel_newton__widened

diagnostic

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’relative’ on the Newton walk: the default rule, whose residual is below tol

none. The row is a diagnostic and states no verdict

coverage 0.9444 to 0.9533, SE ratio 1.0025, mean absolute residual 5.195e-12 SE

reported

relative_reference

continuous_rel_newton__widened

diagnostic

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’relative’ on the Newton walk: the default rule, whose residual is below tol

none. The row is a diagnostic and states no verdict

coverage 0.9474 to 0.9561, SE ratio 1.0032, mean absolute residual 1.893e-10 SE

reported

residual_necessity

ln_ey1__plain

control

law LN (the outcome regression omits the confounding term V, so the initial score has a fixed sign), the mean under treatment, n = 2,000: one-step stopping=’scaled_var’, every threshold times 8: the plain interval, without the residual

the upper limit of the coverage’s exact 99% interval below 0.92

coverage 0.8290 to 0.8440, SE ratio 1.0221, mean absolute residual 0.9828 SE

pass

residual_necessity

ln_ey1__widened

positive

law LN (the outcome regression omits the confounding term V, so the initial score has a fixed sign), the mean under treatment, n = 2,000: one-step stopping=’scaled_var’, every threshold times 8: the widened interval of the same fits

the lower limit of the coverage’s exact 99% interval at least 0.90

coverage 0.9742 to 0.9802, SE ratio 1.0221, mean absolute residual 0.9828 SE

pass

residual_witness

binary_ss_newton__witness

diagnostic

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the Newton walk: the share of draws whose absolute residual is at least 0.01 standard errors

none. The row is a diagnostic and states no verdict

share 0 to 0.000323

reported

residual_witness

binary_ss_one_step__witness

diagnostic

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the one-step walk: the share of draws whose absolute residual is at least 0.01 standard errors

none. The row is a diagnostic and states no verdict

share 0.2938 to 0.3123

reported

residual_witness

binary_sv_newton__witness

diagnostic

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the Newton walk: the share of draws whose absolute residual is at least 0.01 standard errors

none. The row is a diagnostic and states no verdict

share 0 to 0.000323

reported

residual_witness

binary_sv_one_step__witness

positive

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the one-step walk: the share of draws whose absolute residual is at least 0.01 standard errors

the lower limit of the share’s exact 99% interval at least 0.5

share 0.8464 to 0.8607

pass

residual_witness

continuous_ss_newton__witness

diagnostic

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the Newton walk: the share of draws whose absolute residual is at least 0.01 standard errors

none. The row is a diagnostic and states no verdict

share 0 to 0.000323

reported

residual_witness

continuous_ss_one_step__witness

diagnostic

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the one-step walk: the share of draws whose absolute residual is at least 0.01 standard errors

none. The row is a diagnostic and states no verdict

share 0.7420 to 0.7594

reported

residual_witness

continuous_sv_newton__witness

diagnostic

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the Newton walk: the share of draws whose absolute residual is at least 0.01 standard errors

none. The row is a diagnostic and states no verdict

share 0 to 0.000323

reported

residual_witness

continuous_sv_one_step__witness

positive

the canonical-tmle continuous law, a linear outcome and a logistic treatment GLM, in sample, n = 2,000, the ATE: stopping=’scaled_var’ on the one-step walk: the share of draws whose absolute residual is at least 0.01 standard errors

the lower limit of the share’s exact 99% interval at least 0.5

share 0.9979 to 0.9994

pass

step_bound

binary_ss_newton_step_bound__widened

diagnostic

the canonical-tmle binary law, logistic outcome and treatment GLMs, in sample, n = 2,000, the ATE: stopping=’sample_size’ on the Newton walk with step_bound=0.05, the tmle3 pairing: the widened interval

none. The row is a diagnostic and states no verdict

coverage 0.9450 to 0.9539, SE ratio 1.0026, mean absolute residual 0.0041 SE

reported

The eight calibration positives read the widened interval of the ATE on L1. On the Newton walk the rule never binds: the largest residual is \(10^{-10}\) SE on the binary law and 0.0014 SE on the continuous law, no draw reaches 0.01 SE, and coverage and SE ratio equal the relative fit’s on the same draws. Those four cells measure the default estimator under a rule. On the one-step walk scaled_var leaves a residual of at least 0.01 SE on 85% (binary) and 99.9% (continuous) of draws, and sample_size on 30% and 75%. The widened interval covers 0.950 to 0.957 there.

The necessity pair fits LN with every threshold times 8, so the walk stops near a residual of eight times the rule’s cap. The plain interval covers 0.837 and the widened interval 0.977 on the same fits, so the widening is what keeps coverage.

Reported readings#

These rows carry no verdict. The plain interval of every calibration fit covers 0.949 to 0.952, within 0.006 of the widened one, because the residual is small against the standard error on L1. At the declared thresholds LN covers 0.955 plain and 0.960 widened, and the relative fit 0.955. On L2, scaled_var widens the ATE’s coverage from 0.948 to 0.955. The sample_size Newton walk with step_bound=0.05, the tmle3 pairing, covers 0.950; the support key keeps it experimental.

Sizing#

Every size was fixed before the run from the 2,000-draw pilot in tests/studies/option_stopping_pilot.py, on a stream no declared cell reads. Every property cell runs 16,400 replications: the product floor is 3,200, and the arm-pooled predictive rule raises it, because the cells of one law read the same draws. The primary phase runs 3,200. The design test recomputes each count.

Red-cell route#

The study is registered under reporting, and no cell is red. The declared reading is in tests/canonical/option_stopping_point/regenerate.py, and tests/unit/test_option_stopping_point_design.py applies it to the committed tables through gating_findings.

Measured values#

Names beginning margin: are thresholds declared before the run. Everything else is measured from the committed results and checked at the precision printed.

quantity

value

source

replicates

3200

primary replications

n

2000

observations per replication

independent_tests_passed

4

truth tests passing

independent_tests_total

4

truth tests reported

property_cells_passed

28

gated property cells passing

property_cells_total

28

gated property cells reported

max_standardized_bias

0.0674

largest primary standardized bias

min_coverage

0.9547

lowest primary coverage

properties[interval_calibration/binary_sv_one_step__widened]:coverage

0.9540

widened coverage, binary law, scaled_var, one-step

properties[interval_calibration/continuous_sv_one_step__widened]:coverage

0.9573

widened coverage, continuous law, scaled_var, one-step

properties[interval_calibration/binary_ss_newton__widened]:coverage

0.9490

widened coverage, binary law, sample_size, Newton

properties[relative_reference/binary_rel_newton__widened]:coverage

0.9490

the relative fit on the same draws

properties[residual_witness/binary_sv_one_step__witness]:coverage

0.8537

share of draws with a residual of at least 0.01 SE, binary, scaled_var, one-step

properties[residual_witness/continuous_sv_one_step__witness]:coverage

0.9988

the same share, continuous law

properties[residual_witness/binary_ss_one_step__witness]:coverage

0.3030

the same share, binary law, sample_size

properties[residual_witness/continuous_ss_one_step__witness]:coverage

0.7508

the same share, continuous law, sample_size

properties[residual_necessity/ln_ey1__plain]:coverage

0.8366

plain coverage of the necessity fits

properties[residual_necessity/ln_ey1__widened]:coverage

0.9773

widened coverage of the necessity fits

properties[step_bound/binary_ss_newton_step_bound__widened]:coverage

0.9496

the step-bounded Newton walk

margin:confidence_level

0.9900

Monte Carlo confidence level

margin:alpha

0.0500

test size

margin:nominal_coverage

0.9500

nominal interval coverage

margin:bootstrap_replicates

10000

bootstrap replications

margin:standardized_bias

0.2500

standardized-bias margin

margin:coverage_floor

0.9000

primary coverage floor

margin:over_coverage_ceiling

0.9900

descriptive overcoverage threshold

margin:se_ratio_sanity_lower

0.8000

primary SE-ratio lower screen

margin:se_ratio_sanity_upper

1.2000

primary SE-ratio upper screen

margin:calibration_se_ratio_lower

0.9300

calibration SE-ratio lower bound

margin:calibration_se_ratio_upper

1.0700

calibration SE-ratio upper bound

margin:calibration_coverage_lower

0.9200

calibration coverage lower bound

margin:calibration_coverage_upper

0.9800

calibration coverage upper bound

margin:type_i_ceiling

0.1000

type-I upper bound. No cell of this study reads it

margin:paired_difference

0.1500

paired similarity margin in pooled SDs. No cell of this study reads it

margin:rmse_noninferiority

1.1000

RMSE-ratio noninferiority bound. No cell of this study reads it

margin:coverage_noninferiority

-0.0250

coverage-difference noninferiority bound. No cell of this study reads it

margin:calibration_noninferiority

0.0500

calibration-excess noninferiority bound. No cell of this study reads it

margin:minimum_power

0.8000

minimum power lower bound. No cell of this study reads it

margin:root_n_slope

-0.5000

expected root-n slope. No cell of this study reads it

margin:root_n_slope_lower

-0.6250

root-n slope lower bound. No cell of this study reads it

margin:root_n_slope_upper

-0.3750

root-n slope upper bound. No cell of this study reads it

margin:excluded_slope

-0.2500

slower rate the interval must exclude. No cell of this study reads it

margin:shrunken_se_factor

0.7000

negative-control SE multiplier

margin:subject_failure_bound

0.0100

declared share of replications a cell may lose to a recordable fitting failure

margin:subject_failures_allowed

32

the same bound, in primary replications

Limitations#

  • The widened interval is conservative. Its coverage rests on the plain pivot alone, so where the rule binds hard it over-covers (0.977 in the necessity cell). No cell gates an efficiency claim.

  • The Newton cells measure the default estimator. On L1 the Newton walk lands at the relative fit, so those cells show no rule effect and license only that walk.

  • Two laws, in sample. The calibration cells read the ATE on the canonical-tmle binary and continuous laws at n = 2,000 with parametric learners. Cross-fitting, other families and other learners read experimental through the support key.

  • A step bound or iterate="best" under a rule is not covered. The key records them and no row declares them.

  • The bootstrap is refused under a rule, because no source bounds what the residual does to a refit’s law.

  • No comparator. No package widens a Wald interval by its remaining score.

  • The binary rows read today’s normal-quantile interval. The binary arm means are built on the logit scale with \(z\,\widehat{\mathrm{se}}\). The planned small-sample interval for bounded estimates changes that half-width, so the binary-outcome interval rows will be recomputed with the composed half-width, the small-sample half-width plus \(\lvert r_n\rvert\), when it ships.

Reproduction#

tests/canonical/option_stopping_point/regenerate.py regenerates the study and states the run form. It runs no reference process, because the study has no comparator. The manifest records the seeds, the margins, the estimator configuration and the source and result hashes, and the run log records the commit, the clean tree and the wall time.